PurePlus® PCR Plates with Solid Walls
Our disposables for polymerase chain reaction amplification can consistently be relied upon to perform. Our Solid Wall PCR plates are made with a hard polycarbonate frame that does not bend and wells made of ultra thin polypropylene for fast thermal transfer. They work with all major brands of thermocyclers that accept 96 or 384 well plates. Labcon PurePlus® PCR plates are developed using our own in-house laboratory and tested on real thermocyclers.
PurePlus® PCR plates are available for standard and qPCR. Our plates for qPCR fit major thermocyclers that require an optically opaque well for proper functioning.


Ultra Clear & Clean
Our disposables for PCR are not only tested to preclude the presence of RNase and DNase. Every lot is lab tested to ensure there is no ATP, Endotoxin, or DNA on any of the thermocycling supplies we offer you. And since we operate our own micro-biology lab we use our plates, strips, and tubes to test and validate all of our products. So consistency is not only important to you, it is important to us.
PurePlus® plates are available for standard and qPCR that fit most standard thermocylers. These plates can be sealed with our strip caps or film.
Labcon PurePlus® Solid Wall PCR plates are designed to fit many popular thermocyclers including brands like Applied Biosystems®, Eppendorf®, Thermo Scientific®, and Bio Rad®. All our PCR disposables are made from 100% virgin resins to preclude contamination and are lot tested and certified to be free of RNase, DNase, Endotoxin, ATP and DNA.
Our 96 well, 200µL and 100µL and 384 well Solid Wall PCR plates are available in clear natural and opaque white. Our 384 well plates hold 25µL per well and work in all popular 384 well thermocyclers.
PurePlus® PCR plates are autoclavable and can be sealed with most brands of sealing film.
![]() |
Endotoxin Free (Non pyrogenic) Product samples are exposed to endotoxin-free water and the resulting extraction fluid is tested for contamination using the kinetic turbidimetric Limulus Amoebocyte Lysate (LAL) assay protocol and USP guidelines. All products tested must display less than 0.05 EU/ml to be certified free of endotoxin. |
![]() |
Nuclease Free (RNase/DNase) Product samples are exposed to nuclease-free water and the resulting extraction fluid is tested for nuclease activity on commercially available 7.5 kb Poly(A) tailed RNA (1µg) and HindIII-digested DNA (1µg) with a one hour 37°C incubation in appropriate buffers. Results are visualized on an agarose gel with appropriate positive and negative controls. Extraction fluid samples must show no degradation of the nucleic acids by the extraction fluid has occurred for the product to be certified as RNase-free and DNase-free |
![]() |
DNA Free (Human) To confirm the freedom from DNA amplification products are examined by Agarose gel electrophoresis with appropriate positive and negative controls. PCR reactions using extraction fluid must show no PCR- amplified product compared to a positive control containing one picogram of human genomic DNA for the product to be certified as DNA-free. |
![]() |
Adenosine Triphosphate (ATP) Product sample surfaces are tested for the presence of adenosine triphosphate (ATP) using a controlled bioluminescence reaction to detect contamination. Luminescence data is compared to results generated by ATP-free surfaces and surfaces with known amounts of ATP as a positive control. The relative light units result must indicate less than 2 X 10-12 mg/µl of ATP for the product to be certified as ATP free. |
![]() |
Heavy Metals Free Heavy metals have been tested for using the prescribed USP method and confirmed to have levels lower than 1 part per million (1ppm) |
![]() |
Bovine Spongiform Encephalopathy-Transmissible Spongiform Encephalopathy These products contain resins that are processed under conditions proven to exceed the European Union standard as listed in the 22nd Commission Directive EC 98/16/EC of March 5th, 1998 as annexed to council Directive EC 76/768/EEC and further Amendment 419 Annex II of 12 June 2001. |
![]() |
Medical Grade (USP) U.S Pharmacoepia Methods and Guidelines (U.S.P Class VI) are used if applicable. We only use medical grade resins and pre-test all resins for contaminants prior to use. Resins are compliant with FDA CFR title 21-177.1520, 178.3295, 178.3297. |
![]() |
California Prop 65 No Labcon manufactured disposables contain any of the “listed chemicals” as referenced in the California Safe Drinking Water and Toxic Enforcement Act of 1986, (Prop 65) as revised May 25, 2018. |
![]() |
Phthalates & Oleamide All our resins are medical grade and are certified free of Bisphenol A (BPA), Oleamide, DiHEMDA, and Phthalates. |
![]() |
Substances of Very High Concern & REACH All Labcon products are compliant with RoHS Directive 2002/95/EC/-2011/65-2015/863, are free of Substances of Very High Concern (SVHC), and are EU REACH Regulation (EC) No 1907/2006 compliant. |
![]() |
Origin These products are Made in USA and all components meet the requirements for US origin under the USMCA agreement. |
![]() |
U.S. FDA Registered Labcon is a U.S. FDA registered medical device manufacturer. Our facility is registered by the U.S. government to comply with CFR21 GMP regulations for manufacturing medical devices. |
![]() |
CE Compliant As applicable Labcon products meet the requirements for CE marking under regulation 2017/746. |
![]() |
ISO 9001 Quality Registration Labcon has been registered to the ISO 9001 quality management system standard since 1997 and maintains registration to ISO 9001:2015. |
Material | 100% Virgin Polypropylene wells and Polycarbonate frame |
Grade | Medical |
Rating | USP Class VI |
Colors | Various |
Length | Various |
Fits | Most popular thermocycler brands |
Approved Use | Medical, Research, Industrial, Food & Beverage |
Lot Expiration | 6 years |